ECU module
SRC — Scania Retarder Control
45 SOPS parameters in this block@if($fullCount), 1 explained@endif. Generations seen: SRC1.
| Parameter | Observed values | Generations | |
|---|---|---|---|
Eco-roll EnableEcoRoll
|
Enabled on CC and accelerator pedal · Enabled on CC · Disabled | SRC1 | Read |
Accelerator Pedal Logic AcceleratorPedalLogic
|
RQ | SRC1 | listed |
Acc Limit Enable AccLimitEnable
|
Disabled | SRC1 | listed |
Automatic Downshift In Manual Allowed AutomaticDownshiftInManualAllowed
|
ON | SRC1 | listed |
BCI Limit Engine Stop BCILimitEngineStop
|
10 | SRC1 | listed |
CCAP Distance Increase CCAPDistanceIncrease
|
Active | SRC1 | listed |
CCAP Interval Type CCAPIntervalType
|
CCAP active in Standard and Economy mode | SRC1 | listed |
Clutch Ctrl Stgy With Clu Ind PTO ClutchCtrlStgyWithCluIndPTO
|
Standard | SRC1 | listed |
Clutch Torque Adaptation When Active E Dor EK ClutchTorqueAdaptationWhenActiveEDorEK
|
NotActive | SRC1 | listed |
Decrease Clutch Disc Wear DecreaseClutchDiscWear
|
Disabled | SRC1 | listed |
Desired Driveline Status DesiredDrivelineStatus
|
Closed driveline has minimum priority | SRC1 | listed |
Dhsc Brake Light DhscBrakeLight
|
With | SRC1 | listed |
DHSC Type DHSCType
|
Standard | SRC1 | listed |
Direct Gear Function Enable DirectGearFunctionEnable
|
Normal | SRC1 | listed |
Drive On Low Idle Governor DriveOnLowIdleGovernor
|
RevOnLowIdleEnabled | SRC1 | listed |
Driver Proof Opticruise DriverProofOpticruise
|
Disabled | SRC1 | listed |
Engine Speed Limit For PTOED EngineSpeedLimitForPTOED
|
3000 | SRC1 | listed |
Engine Speed Limit For PTOEG1 EngineSpeedLimitForPTOEG1
|
3000 | SRC1 | listed |
Engine Torque Limit For PTOED EngineTorqueLimitForPTOED
|
6000 | SRC1 | listed |
Engine Torque Limit For PTOEG1 EngineTorqueLimitForPTOEG1
|
6000 | SRC1 | listed |
Exh Brake Button ExhBrakeButton
|
DHSC | SRC1 | listed |
Heat Up HeatUp
|
With | SRC1 | listed |
Kickdown Kickdown
|
Enabled | SRC1 | listed |
Limit Max Retarder Brake Torque Type LimitMaxRetarderBrakeTorqueType
|
NoReduction | SRC1 | listed |
Low Rev Gear Selection LowRevGearSelection
|
Automatic | SRC1 | listed |
Lugging Functionality LuggingFunctionality
|
Normal | SRC1 | listed |
Manual Gear Change Limitation ManualGearChangeLimitation
|
Disabled | SRC1 | listed |
Max Start Gear MaxStartGear
|
4 | SRC1 | listed |
Offroad Mode Clutch Disengage OffroadModeClutchDisengage
|
Disabled | SRC1 | listed |
OPC Max Reverse Gear OPCMaxReverseGear
|
R2 | SRC1 | listed |
PTO Activate Manouvering Mode PTOActivateManouveringMode
|
Disabled | SRC1 | listed |
Pto EG1 Feedback Signal PtoEG1FeedbackSignal
|
With | SRC1 | listed |
Pto Eg Clutch Engagement Rate PtoEgClutchEngagementRate
|
Normal | SRC1 | listed |
Pulse And Glide PulseAndGlide
|
Active in Eco | SRC1 | listed |
Reduce Clutch Judder ReduceClutchJudder
|
NotActive | SRC1 | listed |
Remember Manouvering Mode RememberManouveringMode
|
Automatic | SRC1 | listed |
Retarder Performance Mode RetarderPerformanceMode
|
NotActive | SRC1 | listed |
Shift To Crawlers ShiftToCrawlers
|
Disabled | SRC1 | listed |
Show Coming Gear ShowComingGear
|
Disabled | SRC1 | listed |
Split Gear In Neutral SplitGearInNeutral
|
ChoosableAndProgrammedWithOpcLever | SRC1 | listed |
Start Gear Engagement Type StartGearEngagementType
|
Standard | SRC1 | listed |
Start Gear Performance Synchronized StartGearPerformanceSynchronized
|
Normal | SRC1 | listed |
Start Gear Performance Unsynchronized StartGearPerformanceUnsynchronized
|
Normal | SRC1 | listed |
Strict Max Start Gear StrictMaxStartGear
|
Disabled | SRC1 | listed |
Torque Offset TorqueOffset
|
33 | SRC1 | listed |