Engine speed control 1 — deactivate above vehicle speed
SOPS parameter ENGINE_SPEED_CTRL1_DEACT_ABOVE_VEHICLE_SPEED · seen in 70 SOPS files
What it controls
Vehicle speed above which the bodywork engine speed control (channel 1) is switched off, or the condition that ends it. It stops a body-requested engine speed from being held while the truck is driven at road speed — important for cranes and platforms, where engine speed control must only work stationary. Mobile bodies that need a constant engine speed while moving (spreaders, sweepers, mixers) set a value that covers their working speed, or use the parking-brake condition instead. The value should be aligned with the PTO vehicle-speed cut-out so the PTO and the engine speed control stop at the same point and the operator gets a consistent behaviour.
Possible values
5seen in 36 files—
ParkingBrake seen in 34 files—
<km/h>Engine speed control is deactivated above this vehicle speed.
ParkingBrakeEngine speed control is only active while the parking brake is applied.
Related parameters
PTO EG1 — disengage above vehicle speedBWE.PTO_EG1_DEACT_ABOVE_VEHICLE_SPEED |
Without · <km/h> | Read |
Engine speed control 1 — accelerator pedal disableBWE.ENGINE_SPEED_CTRL1_ACC_PEDAL_DISABLE |
With · Without | Read |
Engine speed control 1 — change rateBWE.ENGINE_SPEED_CTRL1_CHANGE_RATE |
1000 · <rpm/s> | Read |
ENGINE SPEED CTRL3 RAMP SPDBWE.ENGINE_SPEED_CTRL3_RAMP_SPD |
1000 | |
ENGINE SPEED CTRL3 REF SPDBWE.ENGINE_SPEED_CTRL3_REF_SPD |
500 |