What it controls

Defines how aggressive the start-gear selection is on a synchronised Opticruise gearbox in performance mode: Normal picks the gear the calibration considers ideal, while the higher setting starts one gear higher to reduce the number of shifts on an empty or lightly loaded vehicle, and the lower setting starts one gear lower for heavy loads and steep yards. Bodybuilders of concrete mixers and refuse vehicles, which pull away fully loaded dozens of times a day, typically ask for the lower setting to protect the clutch. Vehicles with an unsynchronised gearbox use the separate StartGearPerformanceUnsynchronized parameter.

Possible values

Normalseen in 8 files
Calibrated start gear.
High
Start one gear higher (fewer shifts, lighter loads).
Low
Start one gear lower (heavy loads, gradients, clutch protection).

Related parameters

Automatic start gear selection
GMS.AutoStartGear
Auto · Manual Read
Start Gear Performance Synchronized
SRC.StartGearPerformanceSynchronized