PTO EG1 — external control via bodywork interface

SOPS parameter PTO_EG1_EXTCON_WITH · seen in 69 SOPS files

What it controls

Enables the external control input for the EG1 power take-off, so the body can request engagement through the bodywork interface (BCI / BWE inputs) instead of the cab switch. It is the parameter that turns a chassis-cab into a body-controlled PTO installation: crane remote controls, tipper consoles and compactor panels all use it. The bodywork input must be wired to the correct pin on the BWE connector and the activation type must allow a remote request; without both, enabling this parameter alone does nothing. When the parameter is set but the wiring is missing, the PTO simply never engages from the body — check the input status in SDP3 before changing the specification again.

Possible values

Withoutseen in 69 files
Only the cab switch controls the PTO.
With
The bodywork interface input can engage/disengage the PTO.

Related parameters

PTO EG1 — activation type
BWE.PTO_EG1_ACT_TYPE
Manual · Remote · Manual+Remote Read
PTO EG1 — engagement feedback
BWE.PTO_EG1_FEEDBACK
With · Without Read
PTO EG1 — indicator lamp
BWE.PTO_EG1_INDIC_LAMP
Without · With Read
PTO EG1 — reverse gear dependency
BWE.PTO_EG1_GEARBOX_IN_REVERSE_DEP
Without · With Read